| Mfg. Part # | Mfg. Name | CAGE | RNCC | RNVC | ISC | MSDS | SADC | DAC | HCC |
|---|---|---|---|---|---|---|---|---|---|
| 003686 | MOOG INC. | 19156 | C | 1 | 6 | N | |||
| 23D12 | MEAS US LLC | 83186 | 5 | 2 | 6 | ||||
| 23D7 | MEAS US LLC | 83186 | 5 | 1 | 6 | ||||
| 4010186A | SECO TOOLS INC. | 10627 | 3 | 1 | 6 | ||||
| 414-00113-295 | SAGEM DEFENSE SECURITE - GROUPE | FAQ15 | 5 | 2 | 6 | ||||
| 414-00113-295 | SAGEM TELECOMMUNICATIONS | F6151 | 5 | 9 | 6 | ||||
| 414-00113-295 | SFIM INDUSTRIES | F6158 | 5 | 9 | 6 | ||||
| 870102REVC | LOCKHEED MARTIN CORPORATION | 56232 | 5 | 2 | 6 | ||||
| L4005-173-94-52 | KEYSTONE CARBON CO INC | 75263 | 5 | 9 | 6 | ||||
| L4005-173-94S2 | KEYSTONE CARBON CO INC | 75263 | 5 | 1 | 6 | ||||
| TE11C428R | GENERAL ELECTRIC CO | 24446 | 5 | 2 | 6 | ||||
| TE11C428R | SECO TOOLS INC. | 10627 | 5 | 2 | 6 |
| MRC | Requirement Statement | Characteristics |
|---|---|---|
| AEHZ | MAXIMUM OPERATING TEMP | 150.0 DEG CELSIUS |
| AEJC | ZERO POWER TEMP COEFFICIENT OF RESISTANCE IN PERCENT PER DEG CELSIUS | -4.40 |
| AEJA | THERMAL TIME CONSTANT IN SECONDS | 55.0 |
| AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
| ADAT | BODY WIDTH | 0.045 INCHES NOMINAL |
| STYL | STYLE DESIGNATOR | DISK |
| AKNA | INCLOSURE TYPE | ENCAPSULATED |
| TTQY | TERMINAL TYPE AND QUANTITY | 2 WIRE LEAD |
| AEJB | POWER DISSIPATION CONSTANT IN MILLIWATTS PER DEG CELSIUS | 7.0 |
| ABJT | TERMINAL LENGTH | 3.750 INCHES NOMINAL |
| ADAR | BODY OUTSIDE DIAMETER | 0.400 INCHES NOMINAL |
| AEBT | TERMINAL DIAMETER | 0.025 INCHES NOMINAL |
| CRQJ | ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP | -10.0 TO 10.0 |
| CQWD | ZERO POWER RESISTANCE | 295.000 OHMS |