| MRC |
Requirement Statement |
Characteristics |
| CQGB |
CONTACT ACTION STIMULUS |
INCREASE |
| CSCF |
TERMINAL TYPE |
WIRE LEAD |
| CTZB |
CONTACT VOLTAGE RATING IN VOLTS |
115.0 AC AT SEA LEVEL FIRST VOLTAGE 28.0 DC AT SEA LEVEL SECOND VOLTAGE |
| SR-5 |
DESIGN CONTROL REFERENCE |
620296 |
| SR-5 |
THE MANUFACTURERS DATA |
|
| ADAV |
OVERALL DIAMETER |
0.250 INCHES NOMINAL |
| CTHF |
CONTACT LOAD CURRENT RATING |
500.0 MILLIAMPERES RESISTIVE LOAD SINGLE VOLTAGE |
| CTYM |
CONTACT ADJUSTMENT RANGE |
32.00 TO 250.00 ACTUATION POINT DEGREES FAHRENHEIT |
| ADAQ |
BODY LENGTH |
0.938 INCHES NOMINAL |
| SR-5 |
MANUFACTURERS CODE |
58022 |
| CBBL |
FEATURES PROVIDED |
HERMETICALLY SEALED CASE |
| CTYC |
CONTACT ADJUSTABILITY |
ACTUATION POINT ADJUSTABLE, PRESET |
| CRLD |
NONPILE-UP CONTACT ARRANGEMENT |
1 POLE, SINGLE THROW, NORMALLY CLOSED, MOMENTARY ACTION |
| AWTN |
OPERATING TEMP RATING |
250.0 DEG FAHRENHEIT MAXIMUM |
| AXGY |
MOUNTING METHOD |
TERMINAL, WIRE-LEAD |
| CTYX |
CONTACT STIMULUS RATING |
58.00 ACTUATION POINT MINIMUM DEGREES CELSIUS AND 62.00 ACTUATION POINT MAXIMUM DEGREES CELSIUS |