| MRC |
Requirement Statement |
Characteristics |
| AFWE |
HOUSING WIDTH |
2.060 INCHES NOMINAL |
| FEAT |
SPECIAL FEATURES |
WEAPON SYSTEM ESSENTIAL |
| AFUQ |
ACTUATOR STYLE |
ROLLER ARM |
| AFUV |
ACTUATOR ROLLER DIAMETER |
0.750 INCHES NOMINAL |
| CRLD |
NONPILE-UP CONTACT ARRANGEMENT |
1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY SINGLE SWITCH UNIT |
| AKNA |
INCLOSURE TYPE |
FULLY INCLOSED |
| AAQL |
BODY STYLE |
HOLE MOUNTED |
| CSJN |
SWITCH ACTUATING FORCE |
8.0 OUNCES NOMINAL |
| CXQQ |
ACTUATOR MOVEMENT |
0.007 DIFFERENTIAL INCHES MAXIMUM AND 0.219 PRETRAVEL INCHES MAXIMUM |
| CRTL |
CRITICALITY CODE JUSTIFICATION |
FEAT |
| ABHP |
OVERALL LENGTH |
3.660 INCHES NOMINAL |
| AFUW |
ACTUATOR ROLLER WIDTH |
0.312 INCHES NOMINAL |
| CRRM |
SWITCH RELEASE FORCE |
4.0 OUNCES MINIMUM |
| AFWG |
CENTER TO CENTER DISTANCE BETWEEN HOUSING MOUNTING FACILITIES PARALLEL TO HEIGHT |
1.812 INCHES NOMINAL |
| AFWC |
HOUSING HEIGHT |
2.560 INCHES NOMINAL |
| AFWD |
HOUSING LENGTH |
3.660 INCHES NOMINAL |
| AFWH |
CENTER TO CENTER DISTANCE BETWEEN HOUSING MOUNTING FACILITIES PARALLEL TO LENGTH |
2.750 INCHES NOMINAL |
| TTQY |
TERMINAL TYPE AND QUANTITY |
3 SCREW |
| ABFE |
HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION |
DUSTPROOF |
| AFXE |
MAXIMUM VOLTAGE RATING IN VOLTS |
480.0 AC AND 250.0 DC |
| CXQR |
CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE |
250.000 MILLIAMPERES RESISTIVE DC AND 15.000 AMPERES RESISTIVE AC |
| AFGK |
ACTUATOR LENGTH |
1.560 INCHES NOMINAL |
| AGAV |
III END ITEM IDENTIFICATION |
FORRESTAL CLASS CV, BLUE RIDGE CLASS LCC-19, NIMITZ CLASS CVN, EMORY S. LAND CLASS AS, WASP CLASS LHD, DECK MACHINERY, USNS STALWART CLASS TAGOS, TARAWA CLASS LHA, SUPPLY CLASS AOE. |