| MRC |
Requirement Statement |
Characteristics |
| AEJN |
DISTANCE BETWEEN MOUNTING FACILITY CENTERS |
0.937 INCHES MINIMUM AND 0.999 INCHES MAXIMUM |
| CQYJ |
MOUNTING FACILITY PATTERN |
TWO POSITION IN-LINE |
| SR-1 |
NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE |
MIL-S-24236/20 |
| CQGB |
CONTACT ACTION STIMULUS |
INCREASE |
| ABKW |
OVERALL HEIGHT |
0.300 INCHES MAXIMUM |
| ABHP |
OVERALL LENGTH |
1.477 INCHES MINIMUM AND 1.497 INCHES MAXIMUM |
| ZZZK |
SPECIFICATION/STANDARD DATA |
81349-MIL-S-24236/20 GOVERNMENT SPECIFICATION |
| SR-1 |
SPEC/STD CONTROLLING DATA |
|
| CTZB |
CONTACT VOLTAGE RATING IN VOLTS |
115.0 AC AT SEA LEVEL FIRST VOLTAGE 28.0 DC AT SEA LEVEL SECOND VOLTAGE |
| ABTD |
MOUNTING SLOT WIDTH |
0.104 INCHES NOMINAL |
| MEDA |
MEDIA FOR WHICH DESIGNED |
GAS OR LIQUID |
| AXGY |
MOUNTING METHOD |
BRACKET AND SLOT |
| AWTN |
OPERATING TEMP RATING |
-10.0 DEG FAHRENHEIT MINIMUM AND 250.0 DEG FAHRENHEIT MAXIMUM |
| STYL |
STYLE DESIGNATOR |
DISC W/FLANGE |
| CTHF |
CONTACT LOAD CURRENT RATING |
2.0 AMPERES RESISTIVE LOAD AND 1.5 AMPERES INDUCTIVE LOAD AND 500.0 MILLIAMPERES LAMP LOAD FIRST VOLTAGE 2.0 AMPERES RESISTIVE LOAD AND 1.0 AMPERES INDUCTIVE LOAD AND 1.0 AMPERES LAMP LOAD SECOND VOLTAGE |
| ADAU |
BODY HEIGHT |
0.300 INCHES MAXIMUM |
| SR-1 |
DEFINITIVE GOVERNMENT SPEC/STD REFERENCE |
M24236/20-CGFB |
| SR-1 |
MANUFACTURERS CODE |
81349 |
| FREQ |
FREQUENCY IN HERTZ |
60.0 FIRST VOLTAGE |
| CBBL |
FEATURES PROVIDED |
HERMETICALLY SEALED CASE |
| CSCF |
TERMINAL TYPE |
TAB, SOLDER LUG |
| AKBY |
TEMP SENSING ELEMENT TYPE |
INTERNAL SENSOR |
| CTYC |
CONTACT ADJUSTABILITY |
DEACTUATION POINT NOT ADJUSTABLE AND ACTUATION POINT NOT ADJUSTABLE |
| CTYX |
CONTACT STIMULUS RATING |
140.00 ACTUATION POINT NOMINAL DEGREES FAHRENHEIT AND 135.00 DEACTUATION POINT MINIMUM DEGREES FAHRENHEIT AND 138.00 DEACTUATION POINT MAXIMUM DEGREES FAHRENHEIT AND 2.00 DIFFERENTIAL POINT MINIMUM DEGREES FAHRENHEIT AND 5.00 DIFFERENTIAL POINT MAXIMUM DEGREES FAHRENHEIT |
| ABPM |
BODY DIAMETER |
0.660 INCHES MAXIMUM |
| CRLD |
NONPILE-UP CONTACT ARRANGEMENT |
1 POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION |