| MRC |
Requirement Statement |
Characteristics |
| CRNG |
NONPILE-UP MAIN CONTACT ARRANGEMENT |
2 POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION |
| APNQ |
ARC QUENCHING METHOD |
AIR |
| ABMK |
OVERALL WIDTH |
0.875 INCHES MAXIMUM |
| CTDL |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE |
1.0 AMPERES DC RESISTIVE LOAD |
| ADZC |
ENVIRONMENTAL PROTECTION |
DUSTPROOF |
| CWAB |
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS |
28.0 DC |
| AGAV |
III END ITEM IDENTIFICATION |
TRUCK,FORK LIFT |
| ABKW |
OVERALL HEIGHT |
1.375 INCHES MAXIMUM |
| AFJN |
III FRAGILITY FACTOR |
MODERATELY RUGGED |
| AKSL |
III PURPOSE FOR WHICH DESIGNED |
GENERAL |
| AKDX |
WINDING QUANTITY |
1 |
| ABHP |
OVERALL LENGTH |
1.375 INCHES MAXIMUM |
| BBRG |
III STORAGE TYPE |
GENERAL PURPOSE WAREHOUSE |
| APCN |
COIL QUANTITY |
1 |
| ADTV |
III CASE MATERIAL |
PLASTIC |
| CBME |
III CUBIC MEASURE |
1.654 CUBIC INCHES |
| CSXF |
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP |
18.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
| APNP |
DUTY TYPE |
CONTINUOUS |
| AXHR |
MOUNTING FACILITY TYPE AND QUANTITY |
1 PLUG-IN TERMINAL SINGLE MOUNTING FACILITY |
| TTQY |
TERMINAL TYPE AND QUANTITY |
6 PIN ALL FUNCTIONS |