| MRC |
Requirement Statement |
Characteristics |
| CRBZ |
WINDING OPERATING CURRENT |
375.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 1ST SECONDARY 700.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 2ND SECONDARY |
| CWJS |
WINDING OPERATING VOLTAGE |
163.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY 375.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY 203.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
| ABMK |
OVERALL WIDTH |
2.375 INCHES NOMINAL |
| AAJF |
(NON-CORE DATA) THREAD DIRECTION |
RIGHT-HAND |
| AXGY |
MOUNTING METHOD |
THREADED STUD SINGLE GROUP |
| AKPV |
MOUNTING FACILITY QUANTITY |
4 SINGLE GROUP |
| SR-5 |
MANUFACTURERS CODE |
24930 |
| THSD |
THREAD SERIES DESIGNATOR |
UNC SINGLE GROUP |
| AARG |
RELIABILITY INDICATOR |
NOT ESTABLISHED |
| AEHZ |
III MAXIMUM OPERATING TEMP |
130.0 DEG CELSIUS |
| ADAU |
BODY HEIGHT |
3.812 INCHES NOMINAL |
| SR-5 |
THE MANUFACTURERS DATA |
|
| ABHP |
OVERALL LENGTH |
2.750 INCHES NOMINAL |
| CMLP |
THREAD QUANTITY PER INCH |
32 SINGLE GROUP |
| SR-5 |
DESIGN CONTROL REFERENCE |
63453 |
| AAJD |
(NON-CORE DATA) THREAD CLASS |
2A |
| ACZX |
WINDING SHIELDING METHOD |
CORE GROUNDED AND BROUGHT OUT TO TERMINAL AND INTERNAL SHIELD BROUGHT OUT TO TERMINAL SINGLE COMPONENT |
| ABKQ |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH |
2.125 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| AKNA |
INCLOSURE TYPE |
HERMETICALLY SEALED |
| CQLC |
(NON-CORE DATA) WINDING TAP LOCATION |
NEUTRAL TAP |
| ABKR |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH |
1.750 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| CQJX |
NOMINAL THREAD SIZE |
0.138 INCHES SINGLE GROUP |
| ACZB |
FREQUENCY RATING |
380.0 HERTZ MINIMUM AND 420.0 HERTZ MAXIMUM SINGLE COMPONENT |
| TTQY |
TERMINAL TYPE AND QUANTITY |
12 SOLDER STUD |
| BPLC |
WINDING FUNCTION AND QUANTITY |
1 PRIMARY AND 2 SECONDARY SINGLE COMPONENT |
| ABKW |
OVERALL HEIGHT |
4.187 INCHES NOMINAL |
| ACZC |
INPUT-OUTPUT PHASE RELATIONSHIP |
THREE PHASE TO THREE PHASE SINGLE COMPONENT |
| ACZD |
III TRANSFORMER WINDING CONNECTION TYPE |
WYE-DELTA |