| MRC |
Requirement Statement |
Characteristics |
| ABHP |
OVERALL LENGTH |
4.906 INCHES NOMINAL |
| CQGB |
CONTACT ACTION STIMULUS |
INCREASE |
| CSCF |
TERMINAL TYPE |
WIRE LEAD |
| THSD |
THREAD SERIES DESIGNATOR |
NPT SINGLE THREADED BUSHING |
| MEDA |
MEDIA FOR WHICH DESIGNED |
GAS OR LIQUID |
| CTZB |
CONTACT VOLTAGE RATING IN VOLTS |
230.0 AC AT SEA LEVEL FIRST VOLTAGE 115.0 AC AT SEA LEVEL SECOND VOLTAGE |
| CTYS |
CONTACT ADJUSTMENT TYPE |
EXTERNAL DEACTUATION POINT SCREW AND EXTERNAL ACTUATION POINT SCREW |
| ABPM |
BODY DIAMETER |
0.618 INCHES MINIMUM AND 0.625 INCHES MAXIMUM |
| ASDB |
WIDTH ACROSS FLATS |
1.000 INCHES NOMINAL |
| CMLP |
THREAD QUANTITY PER INCH |
14 SINGLE THREADED BUSHING |
| AKBY |
TEMP SENSING ELEMENT TYPE |
IMMERSION WELL |
| CQJX |
NOMINAL THREAD SIZE |
0.500 INCHES SINGLE THREADED BUSHING |
| STYL |
STYLE DESIGNATOR |
CYLINDRICAL W/FLANGE |
| AXGY |
MOUNTING METHOD |
THREADED BUSHING |
| AWTN |
OPERATING TEMP RATING |
800.0 DEG FAHRENHEIT MAXIMUM |
| CTYC |
CONTACT ADJUSTABILITY |
DEACTUATION POINT ADJUSTABLE AND ACTUATION POINT ADJUSTABLE |
| CTHF |
CONTACT LOAD CURRENT RATING |
5.0 AMPERES RESISTIVE LOAD FIRST VOLTAGE 10.0 AMPERES RESISTIVE LOAD SECOND VOLTAGE |
| CRLD |
NONPILE-UP CONTACT ARRANGEMENT |
1 POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION |
| CTYM |
CONTACT ADJUSTMENT RANGE |
-100.00 TO 350.00 ACTUATION POINT DEGREES FAHRENHEIT AND -100.00 TO 350.00 DEACTUATION POINT DEGREES FAHRENHEIT |