| MRC |
Requirement Statement |
Characteristics |
| CTYX |
CONTACT STIMULUS RATING |
164.00 ACTUATION POINT MINIMUM DEGREES FAHRENHEIT AND 174.00 ACTUATION POINT MAXIMUM DEGREES FAHRENHEIT AND 8.00 DIFFERENTIAL POINT MINIMUM DEGREES FAHRENHEIT AND 10.00 DIFFERENTIAL POINT MAXIMUM DEGREES FAHRENHEIT |
| ADAQ |
BODY LENGTH |
1.745 INCHES MINIMUM AND 1.755 INCHES MAXIMUM |
| CQGB |
CONTACT ACTION STIMULUS |
INCREASE |
| AAJD |
THREAD CLASS |
2A SINGLE THREADED BUSHING |
| ABHP |
OVERALL LENGTH |
2.733 INCHES MINIMUM AND 2.783 INCHES MAXIMUM |
| MEDA |
MEDIA FOR WHICH DESIGNED |
GAS OR LIQUID |
| CTZB |
CONTACT VOLTAGE RATING IN VOLTS |
250.0 AC AT SEA LEVEL FIRST VOLTAGE 125.0 AC AT SEA LEVEL SECOND VOLTAGE 30.0 DC AT SEA LEVEL THIRD VOLTAGE |
| CMLP |
THREAD QUANTITY PER INCH |
14 SINGLE THREADED BUSHING |
| FREQ |
FREQUENCY IN HERTZ |
60.0 SINGLE VOLTAGE |
| CSCF |
TERMINAL TYPE |
CONNECTOR, RECEPTACLE |
| THSD |
THREAD SERIES DESIGNATOR |
UNF SINGLE THREADED BUSHING |
| AEVU |
BULB LENGTH |
1.745 INCHES MINIMUM AND 1.755 INCHES MAXIMUM |
| CBBL |
FEATURES PROVIDED |
HERMETICALLY SEALED CASE |
| CQJX |
NOMINAL THREAD SIZE |
0.875 INCHES SINGLE THREADED BUSHING |
| CRLD |
NONPILE-UP CONTACT ARRANGEMENT |
1 POLE, SINGLE THROW, NORMALLY CLOSED, MOMENTARY ACTION |
| AASA |
THREAD LENGTH |
0.312 INCHES NOMINAL SINGLE THREADED BUSHING |
| ASDB |
WIDTH ACROSS FLATS |
0.990 INCHES MINIMUM AND 1.010 INCHES MAXIMUM |
| CTYC |
CONTACT ADJUSTABILITY |
DEACTUATION POINT NOT ADJUSTABLE AND ACTUATION POINT NOT ADJUSTABLE |
| STYL |
STYLE DESIGNATOR |
CYLINDRICAL W/FLANGE |
| CTHF |
CONTACT LOAD CURRENT RATING |
2.0 AMPERES RESISTIVE LOAD FIRST VOLTAGE 4.0 AMPERES RESISTIVE LOAD SECOND VOLTAGE 6.0 AMPERES RESISTIVE LOAD THIRD VOLTAGE |
| AEVV |
BULB DIAMETER |
0.660 INCHES MAXIMUM |
| AXGY |
MOUNTING METHOD |
THREADED BUSHING |
| ABPM |
BODY DIAMETER |
0.660 INCHES MAXIMUM |
| AKBY |
TEMP SENSING ELEMENT TYPE |
BULB |