MRC |
Requirement Statement |
Characteristics |
AEJA |
THERMAL TIME CONSTANT IN SECONDS |
40.0 |
ABJT |
TERMINAL LENGTH |
1.500 INCHES NOMINAL |
AEHY |
AMBIENT TEMP AT FULL RATED POWER |
100.0 DEG CELSIUS |
AEHX |
MAXIMUM POWER DISSIPATION RATING |
125.00 MILLIWATTS |
AEHZ |
MAXIMUM OPERATING TEMP |
150.0 DEG CELSIUS |
SR-1 |
SPEC/STD CONTROLLING DATA |
|
CQWD |
ZERO POWER RESISTANCE |
3.300 KILOHMS |
AARG |
RELIABILITY INDICATOR |
NOT ESTABLISHED |
ADAR |
BODY OUTSIDE DIAMETER |
0.140 INCHES NOMINAL |
SR-1 |
MANUFACTURERS CODE |
95542 |
AEJD |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER |
-75.0 DEG CELSIUS 1ST RESISTANCE-TEMPERATURE POINT 0.0 DEG CELSIUS 2ND RESISTANCE-TEMPERATURE POINT 50.0 DEG CELSIUS 3RD RESISTANCE-TEMPERATURE POINT 75.0 DEG CELSIUS 4TH RESISTANCE-TEMPERATURE POINT 100.0 DEG CELSIUS 5TH RESISTANCE-TEMPERATURE POINT 125.0 DEG CELSIUS 6TH RESISTANCE-TEMPERATURE POINT 150.0 DEG CELSIUS 7TH RESISTANCE-TEMPERATURE POINT |
ADAQ |
BODY LENGTH |
0.406 INCHES NOMINAL |
AEJF |
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT |
-15.0 TO 15.0 ALL RESISTANCE-TEMPERATURE POINTS |
AKNA |
INCLOSURE TYPE |
ENCAPSULATED |
TTQY |
TERMINAL TYPE AND QUANTITY |
2 WIRE LEAD |
STYL |
STYLE DESIGNATOR |
ROD |
AEJE |
ZERO POWER RESISTANCE AT SPECIFIED TEMP |
1.4 KILOHMS 1ST RESISTANCE-TEMPERATURE POINT 2.7 KILOHMS 2ND RESISTANCE-TEMPERATURE POINT 4.1 KILOHMS 3RD RESISTANCE-TEMPERATURE POINT 4.8 KILOHMS 4TH RESISTANCE-TEMPERATURE POINT 5.6 KILOHMS 5TH RESISTANCE-TEMPERATURE POINT 6.4 KILOHMS 6TH RESISTANCE-TEMPERATURE POINT 6.9 KILOHMS 7TH RESISTANCE-TEMPERATURE POINT |
AEBT |
TERMINAL DIAMETER |
0.025 INCHES NOMINAL |
SR-1 |
MFR SOURCE CONTROLLING REFERENCE |
137-803-3329 |
CRQJ |
ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP |
-10.0 TO 10.0 |
AEJC |
ZERO POWER TEMP COEFFICIENT OF RESISTANCE IN PERCENT PER DEG CELSIUS |
0.70 |