| MRC |
Requirement Statement |
Characteristics |
| CTHF |
CONTACT LOAD CURRENT RATING |
3.0 AMPERES RESISTIVE LOAD FIRST VOLTAGE 3.0 AMPERES RESISTIVE LOAD SECOND VOLTAGE |
| CTYX |
CONTACT STIMULUS RATING |
0.10 DIFFERENTIAL POINT NOMINAL DEGREES FAHRENHEIT |
| MEDA |
MEDIA FOR WHICH DESIGNED |
GAS OR LIQUID |
| AXGY |
MOUNTING METHOD |
FLANGE |
| CRLD |
NONPILE-UP CONTACT ARRANGEMENT |
1 POLE, SINGLE THROW, BOTH POSITIONS MAINTAINED |
| CTYM |
CONTACT ADJUSTMENT RANGE |
100.00 TO 750.00 ACTUATION POINT DEGREES FAHRENHEIT |
| ALAQ |
MOUNTING FACILITY CIRCLE RADIUS |
0.625 INCHES NOMINAL |
| CSCF |
TERMINAL TYPE |
THREADED STUD |
| CTYC |
CONTACT ADJUSTABILITY |
DEACTUATION POINT NOT ADJUSTABLE AND ACTUATION POINT ADJUSTABLE, PRESET |
| AKBY |
TEMP SENSING ELEMENT TYPE |
INTERNAL SENSOR |
| AWTN |
OPERATING TEMP RATING |
-65.0 DEG FAHRENHEIT MINIMUM AND 1500.0 DEG FAHRENHEIT MAXIMUM |
| CTZB |
CONTACT VOLTAGE RATING IN VOLTS |
28.0 AC AT SEA LEVEL FIRST VOLTAGE 28.0 AC AT SEA LEVEL SECOND VOLTAGE |
| CQYJ |
MOUNTING FACILITY PATTERN |
THREE POSITION CIRCULAR |
| CQGB |
CONTACT ACTION STIMULUS |
DECREASE |