Home > Switches > FSC 5930 > 5930-00-309-4474

5930-00-309-4474, 5930003094474 NSN Information

Request for Quote

Manufacturer Part Number(s):175-54332, 1HA1-LH

FSC NIIN ITEM NAME
5930 003094474 SWITCH,SENSITIVE
INC ESDC HMIC
0039 P

5930-00-309-4474 MCRD (Master Cross Reference Data)

Mfg. Part # Mfg. Name CAGE RNCC RNVC ISC MSDS SADC DAC HCC
175-54332 BOEING COMPANY THE 43999 5 9 6
1HA1-LH HONEYWELL INTERNATIONAL INC. 91929 3 9 6

5930-00-309-4474 Characteristics

MRC Requirement Statement Characteristics
AFWC HOUSING HEIGHT 1.094 INCHES MINIMUM AND 1.156 INCHES MAXIMUM
AFWJ CENTER TO CENTER DISTANCE BETWEEN HOUSING MOUNTING FACILITIES PARALLEL TO WIDTH 1.870 INCHES MINIMUM AND 1.880 INCHES MAXIMUM
AFUR ACTUATOR DIAMETER 0.243 INCHES MINIMUM AND 0.248 INCHES MAXIMUM
AFUQ ACTUATOR STYLE ROUND
AFWH CENTER TO CENTER DISTANCE BETWEEN HOUSING MOUNTING FACILITIES PARALLEL TO LENGTH 2.432 INCHES MINIMUM AND 2.442 INCHES MAXIMUM
AKNA INCLOSURE TYPE FULLY INCLOSED
AAQL BODY STYLE HOLE MOUNTED
AFXE MAXIMUM VOLTAGE RATING IN VOLTS 28.0 DC
ADAQ BODY LENGTH 1.940 INCHES NOMINAL
AEBV UNTHREADED MOUNTING HOLE DIAMETER 0.139 INCHES NOMINAL
FEAT SPECIAL FEATURES ACTUATOR ON LEFT HAND SIDE
CRLD NONPILE-UP CONTACT ARRANGEMENT 1 POLE, DOUBLE THROW, BOTH POSITIONS MAINTAINED SINGLE SWITCH UNIT
AFUS ACTUATOR HEIGHT 0.849 INCHES MINIMUM AND 0.869 INCHES MAXIMUM
CRRM SWITCH RELEASE FORCE 4.0 OUNCES MINIMUM
AFWE HOUSING WIDTH 1.095 INCHES MINIMUM AND 1.155 INCHES MAXIMUM
ABKQ CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH 1.000 INCHES NOMINAL
CXQQ ACTUATOR MOVEMENT 118.0 PRETRAVEL DEGREES NOMINAL AND 100.0 OVERTRAVEL DEGREES MINIMUM AND 10.0 DIFFERENTIAL DEGREES MAXIMUM
AXGY MOUNTING METHOD THREADED HOLE
CSJN SWITCH ACTUATING FORCE 192.0 OUNCES MAXIMUM
AFWD HOUSING LENGTH 2.791 INCHES MINIMUM AND 2.843 INCHES MAXIMUM
TTQY TERMINAL TYPE AND QUANTITY 3 SCREW
ADAT BODY WIDTH 0.687 INCHES NOMINAL
CXQR CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE 15.000 AMPERES RESISTIVE DC AND 5.000 AMPERES INDUCTIVE DC
ABFE HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION DUSTPROOF