| MRC |
Requirement Statement |
Characteristics |
| AGAV |
III END ITEM IDENTIFICATION |
A-6E INTRUDER, EA-6B PROWLER AIRCRAFT. |
| TTQY |
TERMINAL TYPE AND QUANTITY |
4 SCREW |
| AJWX |
MOUNTING SURFACE TO TERMINAL END DISTANCE |
1.350 INCHES NOMINAL |
| FEAT |
SPECIAL FEATURES |
WEAPON SYSTEM ESSENTIAL |
| THSD |
THREAD SERIES DESIGNATOR |
UNS |
| AFUQ |
ACTUATOR STYLE |
ROUND |
| AKNA |
INCLOSURE TYPE |
FULLY INCLOSED |
| ABXD |
BUSHING LENGTH |
0.470 INCHES NOMINAL |
| ADAQ |
BODY LENGTH |
1.320 INCHES NOMINAL |
| CRTL |
CRITICALITY CODE JUSTIFICATION |
FEAT |
| AFUR |
ACTUATOR DIAMETER |
0.420 INCHES NOMINAL |
| AAQL |
BODY STYLE |
BUSHING MOUNT |
| AFXE |
MAXIMUM VOLTAGE RATING IN VOLTS |
115.0 AC AND 28.0 DC |
| CRLD |
NONPILE-UP CONTACT ARRANGEMENT |
1 TWO CIRCUIT, DOUBLE BREAK/DOUBLE MAKE, BOTH POSITIONS MAINTAINED SINGLE SWITCH UNIT |
| AFUX |
ACTUATOR POSITION-ACTION RELATIONSHIP |
LEFT POSITION MAINTAINED AND RIGHT POSITION MAINTAINED |
| CQJX |
NOMINAL THREAD SIZE |
0.469 INCHES |
| CMLP |
THREAD QUANTITY PER INCH |
32 |
| CXQR |
CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE |
20.000 AMPERES RESISTIVE DC AND 15.000 AMPERES RESISTIVE AC |
| AXGY |
MOUNTING METHOD |
THREADED BUSHING |
| AFUS |
ACTUATOR HEIGHT |
1.050 INCHES NOMINAL |
| ADAT |
BODY WIDTH |
0.890 INCHES NOMINAL |
| ABFE |
HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION |
DUSTPROOF |