Home > Capacitor, Fuse, Circuit Breaker > FSC 5925 > 5925-00-009-6791

5925-00-009-6791, 5925000096791 NSN Information

Request for Quote

Manufacturer Part Number(s):2G4-5

FSC NIIN ITEM NAME
5925 000096791 CIRCUIT BREAKER
INC ESDC HMIC
0013 P

5925-00-009-6791 MCRD (Master Cross Reference Data)

Mfg. Part # Mfg. Name CAGE RNCC RNVC ISC MSDS SADC DAC HCC
2G4-5 ELLIS & WATTS INTERNATIONAL LLC 98437 3 2 C

5925-00-009-6791 Characteristics

MRC Requirement Statement Characteristics
AAQL BODY STYLE MULTIPOLE-MULTIPLE ACTUATOR TYPE
CSSX SWITCH CURRENT RATING AND TYPE IN AMPS 2.5 AC AND 1.0 DC
AEBQ CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH 0.750 INCHES NOMINAL
AEGJ SWITCH CONTACT ARRANGEMENT SINGLE POLE, DOUBLE THROW
CPLM MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE 30.0 AMPERES AC ALL LOCATIONS
PKWT III UNPACKAGED UNIT WEIGHT 14.000 OUNCES
CPRY EXTERNAL ACTUATOR LINKAGE ARRANGEMENT ONE, TWO, AND THREE LINKED
APNQ III ARC QUENCHING METHOD MAGNETIC BLOWOUT
CSWP SWITCH VOLTAGE RATING AND TYPE IN VOLTS 250.0 AC AND 50.0 DC
CPRW ACTUATOR FUNCTION TRIP-RESET
CPRF OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS 120.0 AC ALL LOCATIONS
CPRL TRIP RELEASE CHARACTERISTIC TIME DELAY ALL LOCATIONS
AEBY DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH 2.060 INCHES NOMINAL
CPRQ RESET METHOD MANUAL
CRTK SWITCH TERMINAL TYPE TURRET
CPRN ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT 150.0 ALL LOCATIONS
CQXF INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED FUNGUS RESISTANT AND MOISTURE RESISTANT
ADAT BODY WIDTH 2.280 INCHES NOMINAL
BBRJ III SPECIAL HANDLING FEATURE MAGNETIC
CPRJ TRIP RELEASE METHOD MAGNETIC-HYDRAULIC ALL LOCATIONS
FREQ FREQUENCY IN HERTZ 400.0 ALL LOCATIONS
TTQY TERMINAL TYPE AND QUANTITY 6 THREADED STUD
AXHR MOUNTING FACILITY TYPE AND QUANTITY 6 THREADED HOLE
CPRZ AUXILIARY SWITCH FUNCTION AND QUANTITY 1 ALARM
CQSM SWITCH LOCATION AND POSITION DESIGNATION EXTERNAL AT POLE ONE
THSD THREAD SERIES DESIGNATOR UNC
CQWN TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT 2.500 MINIMUM AT 200 PCT AND 8.500 MAXIMUM AT 200 PCT ALL LOCATIONS
ADAQ BODY LENGTH 2.530 INCHES NOMINAL
ADTV CASE MATERIAL PLASTIC
CPRR MAIN CONTACT TRIPPING MECHANISM TYPE TRIP FREE
CPRT MANUAL ACTUATOR TYPE AND QUANTITY 3 TOGGLE
AJWX MOUNTING SURFACE TO TERMINAL END DISTANCE 2.480 INCHES NOMINAL
CMLP THREAD QUANTITY PER INCH 32
AEHA DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH 0.750 INCHES NOMINAL
BBRG III STORAGE TYPE GENERAL PURPOSE WAREHOUSE
CQJX NOMINAL THREAD SIZE 0.138 INCHES
AEBP CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH 1.940 INCHES NOMINAL
CPRG MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS 1500.0 AC ALL LOCATIONS
AKPX POLE QUANTITY 3
AJEC BOSS HEIGHT 0.150 INCHES NOMINAL
CPSM INTERNAL TRIP RELEASE CONFIGURATION SERIES TRIP ALL LOCATIONS
CPRH CIRCUIT PROTECTION TYPE OVERCURRENT ALL LOCATIONS
CPRX ACTUATOR POSITION DESIGNATION AT EACH POLE