| MRC |
Requirement Statement |
Characteristics |
| MEDA |
MEDIA FOR WHICH DESIGNED |
GAS |
| CTYC |
CONTACT ADJUSTABILITY |
ACTUATION POINT ADJUSTABLE |
| AJZC |
PRESSURE SWITCH TYPE |
DIFFERENTIAL |
| AXGY |
MOUNTING METHOD |
PLUG-IN |
| CRLD |
NONPILE-UP CONTACT ARRANGEMENT |
1 POLE, DOUBLE THROW, TWO POSITIONS MOMENTARY |
| CSCF |
TERMINAL TYPE |
CONNECTOR, RECEPTACLE |
| CTYM |
CONTACT ADJUSTMENT RANGE |
0.87 TO 0.95 ACTUATION POINT KNOTS |
| AWTN |
OPERATING TEMP RATING |
-273.1 DEG CELSIUS MINIMUM AND 50.0 DEG CELSIUS MAXIMUM |
| CQYJ |
MOUNTING FACILITY PATTERN |
FOUR POSITION RECTANGULAR |
| CTHF |
CONTACT LOAD CURRENT RATING |
5.0 AMPERES INDUCTIVE LOAD SINGLE VOLTAGE |
| CQGB |
CONTACT ACTION STIMULUS |
DECREASE |