| MRC |
Requirement Statement |
Characteristics |
| ADAQ |
BODY LENGTH |
0.270 INCHES MINIMUM AND 0.300 INCHES MAXIMUM |
| AEHY |
AMBIENT TEMP AT FULL RATED POWER |
100.0 DEG CELSIUS |
| AEHX |
MAXIMUM POWER DISSIPATION RATING |
125.00 MILLIWATTS |
| AEHZ |
MAXIMUM OPERATING TEMP |
125.0 DEG CELSIUS |
| AEBT |
TERMINAL DIAMETER |
0.018 INCHES MINIMUM AND 0.022 INCHES MAXIMUM |
| CQWD |
ZERO POWER RESISTANCE |
100.000 OHMS |
| AARG |
RELIABILITY INDICATOR |
NOT ESTABLISHED |
| AEJA |
THERMAL TIME CONSTANT IN SECONDS |
60.0 |
| ABDN |
III TERMINAL SURFACE TREATMENT |
TIN |
| TEST |
TEST DATA DOCUMENT |
30890-40-001066 STANDARD (INCLUDES INDUSTRY OR ASSOCIATION STANDARDS, INDIVIDUAL MANUFACTUREER STANDARDS, ETC.). |
| ADAR |
BODY OUTSIDE DIAMETER |
0.085 INCHES MINIMUM AND 0.105 INCHES MAXIMUM |
| TTQY |
TERMINAL TYPE AND QUANTITY |
2 WIRE LEAD |
| AKNA |
INCLOSURE TYPE |
HERMETICALLY SEALED |
| STYL |
STYLE DESIGNATOR |
ROD |
| ABJT |
TERMINAL LENGTH |
1.200 INCHES MINIMUM |
| CRQJ |
ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP |
-10.0 TO 10.0 |
| AEJC |
ZERO POWER TEMP COEFFICIENT OF RESISTANCE IN PERCENT PER DEG CELSIUS |
0.70 |