| MRC |
Requirement Statement |
Characteristics |
| AFUR |
ACTUATOR DIAMETER |
0.430 INCHES NOMINAL |
| THSD |
THREAD SERIES DESIGNATOR |
UNS |
| AFUQ |
ACTUATOR STYLE |
ROUND |
| TTQY |
TERMINAL TYPE AND QUANTITY |
2 SCREW |
| CRLD |
NONPILE-UP CONTACT ARRANGEMENT |
1 POLE, SINGLE THROW, BOTH POSITIONS MAINTAINED SINGLE SWITCH UNIT |
| AFXE |
MAXIMUM VOLTAGE RATING IN VOLTS |
230.0 AC AND 250.0 DC |
| AKNA |
INCLOSURE TYPE |
FULLY INCLOSED |
| CBBL |
FEATURES PROVIDED |
ACTUATOR SEAL |
| ABXD |
BUSHING LENGTH |
0.470 INCHES NOMINAL |
| AAQL |
BODY STYLE |
BUSHING MOUNT |
| ADAT |
BODY WIDTH |
0.635 INCHES MAXIMUM |
| CXQR |
CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE |
500.000 MILLIAMPERES RESISTIVE DC AND 6.000 AMPERES RESISTIVE AC |
| AFUY |
ACTUATOR POSITION-LOCKING RELATIONSHIP |
UP POSITION NO LOCKING ACTION AND CENTER POSITION LOCKED IN |
| CQJX |
NOMINAL THREAD SIZE |
0.469 INCHES |
| CMLP |
THREAD QUANTITY PER INCH |
32 |
| AFUX |
ACTUATOR POSITION-ACTION RELATIONSHIP |
UP POSITION MAINTAINED AND CENTER POSITION MAINTAINED |
| ADAQ |
BODY LENGTH |
1.270 INCHES MAXIMUM |
| AXGY |
MOUNTING METHOD |
THREADED BUSHING |
| AFUS |
ACTUATOR HEIGHT |
1.050 INCHES NOMINAL |
| ADAU |
BODY HEIGHT |
0.890 INCHES MINIMUM AND 0.930 INCHES MAXIMUM |
| ABFE |
HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION |
DUSTPROOF |