| MRC |
Requirement Statement |
Characteristics |
| AKNA |
INCLOSURE TYPE |
ENCASED |
| CQWD |
ZERO POWER RESISTANCE |
10.500 KILOHMS |
| CTGT |
III REFERENCE TEMP IN DEG CELSIUS |
25.0 |
| AARG |
RELIABILITY INDICATOR |
NOT ESTABLISHED |
| AEJE |
ZERO POWER RESISTANCE AT SPECIFIED TEMP |
650.0 KILOHMS 1ST RESISTANCE-TEMPERATURE POINT 64.0 KILOHMS 2ND RESISTANCE-TEMPERATURE POINT 30.5 KILOHMS 3RD RESISTANCE-TEMPERATURE POINT 3.975 KILOHMS 4TH RESISTANCE-TEMPERATURE POINT 2.840 KILOHMS 5TH RESISTANCE-TEMPERATURE POINT 2.0 KILOHMS 6TH RESISTANCE-TEMPERATURE POINT 1.875 KILOHMS 7TH RESISTANCE-TEMPERATURE POINT 1.505 KILOHMS 8TH RESISTANCE-TEMPERATURE POINT 930.0 OHMS 9TH RESISTANCE-TEMPERATURE POINT |
| AEJA |
THERMAL TIME CONSTANT IN SECONDS |
8.0 |
| ADAR |
BODY OUTSIDE DIAMETER |
0.035 INCHES NOMINAL |
| ABJT |
TERMINAL LENGTH |
17.000 INCHES NOMINAL |
| TTQY |
TERMINAL TYPE AND QUANTITY |
2 WIRE LEAD |
| AEJF |
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT |
-27.0 TO 27.0 1ST RESISTANCE-TEMPERATURE POINT -17.0 TO 17.0 2ND RESISTANCE-TEMPERATURE POINT -14.0 TO 14.0 3RD RESISTANCE-TEMPERATURE POINT -8.0 TO 8.0 4TH RESISTANCE-TEMPERATURE POINT -5.0 TO 5.0 5TH RESISTANCE-TEMPERATURE POINT -5.0 TO 5.0 6TH RESISTANCE-TEMPERATURE POINT -5.0 TO 5.0 7TH RESISTANCE-TEMPERATURE POINT -5.0 TO 5.0 8TH RESISTANCE-TEMPERATURE POINT -10.0 TO 10.0 9TH RESISTANCE-TEMPERATURE POINT |
| AEJB |
POWER DISSIPATION CONSTANT IN MILLIWATTS PER DEG CELSIUS |
0.35 |
| AEJC |
ZERO POWER TEMP COEFFICIENT OF RESISTANCE IN PERCENT PER DEG CELSIUS |
-7.50 |
| AEBT |
TERMINAL DIAMETER |
0.040 INCHES NOMINAL |
| AEJD |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER |
-55.0 DEG CELSIUS 1ST RESISTANCE-TEMPERATURE POINT -15.0 DEG CELSIUS 2ND RESISTANCE-TEMPERATURE POINT 0.0 DEG CELSIUS 3RD RESISTANCE-TEMPERATURE POINT 50.0 DEG CELSIUS 4TH RESISTANCE-TEMPERATURE POINT 60.0 DEG CELSIUS 5TH RESISTANCE-TEMPERATURE POINT 71.0 DEG CELSIUS 6TH RESISTANCE-TEMPERATURE POINT 75.0 DEG CELSIUS 7TH RESISTANCE-TEMPERATURE POINT 80.0 DEG CELSIUS 8TH RESISTANCE-TEMPERATURE POINT 100.0 DEG CELSIUS 9TH RESISTANCE-TEMPERATURE POINT |
| CRQJ |
ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP |
-10.0 TO 10.0 |
| STYL |
STYLE DESIGNATOR |
BEAD |