Home > Switches > FSC 5930 > 5930-00-189-2394

5930-00-189-2394, 5930001892394 NSN Information

Request for Quote

Manufacturer Part Number(s):2137130G001, 975-0328-001

FSC NIIN ITEM NAME
5930 001892394 SWITCH,THERMOSTATIC
INC ESDC HMIC
0045 P

5930-00-189-2394 MCRD (Master Cross Reference Data)

Mfg. Part # Mfg. Name CAGE RNCC RNVC ISC MSDS SADC DAC HCC
2137130G001 ITT CORPORATION 28527 3 2 2
975-0328-001 HONEYWELL INTERNATIONAL INC 97896 5 2 2

5930-00-189-2394 Characteristics

MRC Requirement Statement Characteristics
MEDA MEDIA FOR WHICH DESIGNED GAS
CMLP THREAD QUANTITY PER INCH 32 ALL THREADED STUD
CTHF CONTACT LOAD CURRENT RATING 2.0 AMPERES RESISTIVE LOAD FIRST VOLTAGE 5.0 AMPERES RESISTIVE LOAD SECOND VOLTAGE 1.0 AMPERES RESISTIVE LOAD THIRD VOLTAGE 5.0 AMPERES RESISTIVE LOAD FOURTH VOLTAGE
ADAV OVERALL DIAMETER 0.600 INCHES MAXIMUM
ABKW OVERALL HEIGHT 0.902 INCHES MAXIMUM
AAJD THREAD CLASS 2A ALL THREADED STUD
ADAU BODY HEIGHT 0.437 INCHES MAXIMUM
AKBY TEMP SENSING ELEMENT TYPE DISC
CTZB CONTACT VOLTAGE RATING IN VOLTS 115.0 AC AT SEA LEVEL FIRST VOLTAGE 28.0 DC AT SEA LEVEL SECOND VOLTAGE 115.0 AC AT ALTITUDE THIRD VOLTAGE 28.0 DC AT ALTITUDE FOURTH VOLTAGE
THSD THREAD SERIES DESIGNATOR UNC ALL THREADED STUD
CQJX NOMINAL THREAD SIZE 0.138 INCHES ALL THREADED STUD
AXGY MOUNTING METHOD THREADED STUD
STYL STYLE DESIGNATOR DISC
FREQ FREQUENCY IN HERTZ 60.0 SINGLE VOLTAGE
CTYX CONTACT STIMULUS RATING -36.00 ACTUATION POINT MINIMUM DEGREES FAHRENHEIT AND -50.00 ACTUATION POINT MAXIMUM DEGREES FAHRENHEIT AND -21.00 DEACTUATION POINT MINIMUM DEGREES FAHRENHEIT AND -35.00 DEACTUATION POINT MAXIMUM DEGREES FAHRENHEIT AND 15.00 DIFFERENTIAL POINT NOMINAL DEGREES FAHRENHEIT
CBBL FEATURES PROVIDED HERMETICALLY SEALED CASE
CSCF TERMINAL TYPE TAB, SOLDER LUG
CTYC CONTACT ADJUSTABILITY DEACTUATION POINT NOT ADJUSTABLE AND ACTUATION POINT NOT ADJUSTABLE
AASA THREAD LENGTH 0.250 INCHES NOMINAL ALL THREADED STUD
CRLD NONPILE-UP CONTACT ARRANGEMENT 1 POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION
CQGB CONTACT ACTION STIMULUS DECREASE