Home > Capacitor, Fuse, Circuit Breaker > FSC 5925 > 5925-00-088-9505

5925-00-088-9505, 5925000889505 NSN Information

Request for Quote

Manufacturer Part Number(s):70-761E5AMP, AM-12-761E5AMP

FSC NIIN ITEM NAME
5925 000889505 CIRCUIT BREAKER
INC ESDC HMIC
0013 P

5925-00-088-9505 MCRD (Master Cross Reference Data)

Mfg. Part # Mfg. Name CAGE RNCC RNVC ISC MSDS SADC DAC HCC
70-761E5AMP EATON CORP 74193 3 9 E
AM-12-761E5AMP EATON CORP 74193 5 9 E

5925-00-088-9505 Characteristics

MRC Requirement Statement Characteristics
CPSM INTERNAL TRIP RELEASE CONFIGURATION SERIES TRIP SINGLE LOCATION
AEBY DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH 2.052 INCHES MINIMUM AND 2.072 INCHES MAXIMUM
AXHR MOUNTING FACILITY TYPE AND QUANTITY 2 THREADED HOLE
FREQ FREQUENCY IN HERTZ 400.0 SINGLE LOCATION
CPRH CIRCUIT PROTECTION TYPE OVERCURRENT SINGLE LOCATION
CPRL TRIP RELEASE CHARACTERISTIC TIME DELAY SINGLE LOCATION
CQWN TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT 7.000 MINIMUM AT 150 PCT AND 4.000 MAXIMUM AT 200 PCT SINGLE LOCATION
ADAT BODY WIDTH 0.740 INCHES MINIMUM AND 0.760 INCHES MAXIMUM
ADAQ BODY LENGTH 2.490 INCHES MINIMUM AND 2.510 INCHES MAXIMUM
APNQ III ARC QUENCHING METHOD MAGNETIC BLOWOUT
CPRW ACTUATOR FUNCTION TRIP-RESET
CPRT MANUAL ACTUATOR TYPE AND QUANTITY 1 TOGGLE
CPRJ TRIP RELEASE METHOD MAGNETIC SINGLE LOCATION
CPRQ RESET METHOD MANUAL
TTQY TERMINAL TYPE AND QUANTITY 2 THREADED STUD
CPRG MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS 1500.0 AC SINGLE LOCATION
AFJN III FRAGILITY FACTOR MODERATELY RUGGED
AAQL BODY STYLE SINGLE POLE TYPE
CPRF OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS 115.0 AC SINGLE LOCATION
THSD THREAD SERIES DESIGNATOR UNC
ADTV CASE MATERIAL PLASTIC
CPRR MAIN CONTACT TRIPPING MECHANISM TYPE TRIP FREE
AJEC BOSS HEIGHT 0.130 INCHES MINIMUM AND 0.150 INCHES MAXIMUM
CPLM MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE 5.0 AMPERES AC SINGLE LOCATION
CMLP THREAD QUANTITY PER INCH 32
BBRG III STORAGE TYPE GENERAL PURPOSE WAREHOUSE
AKPX POLE QUANTITY 1
AEBP CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH 1.928 INCHES MINIMUM AND 1.948 INCHES MAXIMUM
CQJX NOMINAL THREAD SIZE 0.164 INCHES
CPRN ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT 150.0 SINGLE LOCATION
AJWX MOUNTING SURFACE TO TERMINAL END DISTANCE 2.461 INCHES MINIMUM AND 2.481 INCHES MAXIMUM
CQXF INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED FUNGUS PROOF AND SALT WATER RESISTANT
CPRX ACTUATOR POSITION DESIGNATION AT POLE ONE