Home > Capacitor, Fuse, Circuit Breaker > FSC 5925 > 5925-00-140-6367

5925-00-140-6367, 5925001406367 NSN Information

Request for Quote

Manufacturer Part Number(s):260-0994-010, APL-111-1-43-753, APL111-1130-010

FSC NIIN ITEM NAME
5925 001406367 CIRCUIT BREAKER
INC ESDC HMIC
0013 P

5925-00-140-6367 MCRD (Master Cross Reference Data)

Mfg. Part # Mfg. Name CAGE RNCC RNVC ISC MSDS SADC DAC HCC
260-0994-010 ROCKWELL COLLINS INC. 13499 3 9 2
APL-111-1-43-753 SENSATA TECHNOLOGIES MARYLAND INC 81541 5 2 2
APL111-1130-010 SENSATA TECHNOLOGIES MARYLAND INC 81541 5 2 2

5925-00-140-6367 Characteristics

MRC Requirement Statement Characteristics
AJEC BOSS HEIGHT 0.135 INCHES MINIMUM AND 0.165 INCHES MAXIMUM
CPRJ TRIP RELEASE METHOD MAGNETIC ALL LOCATIONS
AAQL BODY STYLE MULTIPOLE-MULTIPLE ACTUATOR TYPE
CQWN TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT 9.000 MINIMUM AT 200 PCT AND 70.000 MAXIMUM AT 200 PCT ALL LOCATIONS
AEBQ CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH 0.735 INCHES MINIMUM AND 0.765 INCHES MAXIMUM
ADAQ BODY LENGTH 2.480 INCHES MINIMUM AND 2.500 INCHES MAXIMUM
CQXF INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED MOISTURE RESISTANT AND SALT SPRAY PROOF AND SHOCK RESISTANT AND VIBRATION RESISTANT
CPRY EXTERNAL ACTUATOR LINKAGE ARRANGEMENT ONE, TWO, AND THREE LINKED
APNQ III ARC QUENCHING METHOD MAGNETIC BLOWOUT
CPRW ACTUATOR FUNCTION TRIP-RESET
CPRF OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS 250.0 AC ALL LOCATIONS
CPRL TRIP RELEASE CHARACTERISTIC TIME DELAY ALL LOCATIONS
CPRQ RESET METHOD MANUAL
AFJN III FRAGILITY FACTOR MODERATELY RUGGED
FREQ FREQUENCY IN HERTZ 400.0 ALL LOCATIONS
TTQY TERMINAL TYPE AND QUANTITY 6 THREADED STUD
AXHR MOUNTING FACILITY TYPE AND QUANTITY 6 THREADED HOLE
THSD THREAD SERIES DESIGNATOR UNC
PKWT III UNPACKAGED UNIT WEIGHT 11.100 OUNCES
ADTV CASE MATERIAL PLASTIC
CPRR MAIN CONTACT TRIPPING MECHANISM TYPE TRIP FREE
CPRT MANUAL ACTUATOR TYPE AND QUANTITY 3 TOGGLE
AEBY DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH 2.050 INCHES MINIMUM AND 2.070 INCHES MAXIMUM
CPRG MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS 1000.0 AC ALL LOCATIONS
ADAT BODY WIDTH 2.265 INCHES MAXIMUM
CMLP THREAD QUANTITY PER INCH 32
BBRG III STORAGE TYPE GENERAL PURPOSE WAREHOUSE
CQJX NOMINAL THREAD SIZE 0.138 INCHES
AEBP CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH 1.925 INCHES MINIMUM AND 1.955 INCHES MAXIMUM
CPRN ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT 115.0 ALL LOCATIONS
AEHA DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH 0.735 INCHES MINIMUM AND 0.765 INCHES MAXIMUM
CPLM MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE 75.0 AMPERES AC ALL LOCATIONS
AKPX POLE QUANTITY 3
CPSM INTERNAL TRIP RELEASE CONFIGURATION SERIES TRIP ALL LOCATIONS
CPRH CIRCUIT PROTECTION TYPE OVERCURRENT ALL LOCATIONS
CPRX ACTUATOR POSITION DESIGNATION AT EACH POLE
AAJE THREAD PITCH DIAMETERS 0.1177 TO 0.1214 INCHES
AJWX MOUNTING SURFACE TO TERMINAL END DISTANCE 2.491 INCHES MAXIMUM