| MRC |
Requirement Statement |
Characteristics |
| CQYJ |
MOUNTING FACILITY PATTERN |
TWO POSITION IN-LINE |
| ABMK |
OVERALL WIDTH |
2.500 INCHES NOMINAL |
| CQGB |
CONTACT ACTION STIMULUS |
INCREASE |
| CTYC |
CONTACT ADJUSTABILITY |
ACTUATION POINT ADJUSTABLE |
| CTHF |
CONTACT LOAD CURRENT RATING |
25.0 AMPERES RESISTIVE LOAD FIRST VOLTAGE 12.5 AMPERES RESISTIVE LOAD SECOND VOLTAGE |
| MEDA |
MEDIA FOR WHICH DESIGNED |
GAS OR LIQUID |
| CTYM |
CONTACT ADJUSTMENT RANGE |
110.00 TO 170.00 ACTUATION POINT DEGREES FAHRENHEIT |
| AEJN |
DISTANCE BETWEEN MOUNTING FACILITY CENTERS |
2.000 INCHES NOMINAL |
| AXGY |
MOUNTING METHOD |
BRACKET AND UNTHREADED HOLE |
| CRLD |
NONPILE-UP CONTACT ARRANGEMENT |
2 TWO CIRCUIT, ONE POSITION MOMENTARY |
| ABKW |
OVERALL HEIGHT |
1.250 INCHES NOMINAL |
| CSCF |
TERMINAL TYPE |
SCREW |
| AKBY |
TEMP SENSING ELEMENT TYPE |
INTERNAL SENSOR |
| AEBV |
UNTHREADED MOUNTING HOLE DIAMETER |
0.219 INCHES NOMINAL |
| CTZB |
CONTACT VOLTAGE RATING IN VOLTS |
120.0 AC AT SEA LEVEL FIRST VOLTAGE 480.0 AC AT SEA LEVEL SECOND VOLTAGE |
| CTYS |
CONTACT ADJUSTMENT TYPE |
INTERNAL ACTUATION POINT SCREW WITH SCALE |