| MRC |
Requirement Statement |
Characteristics |
| AJWX |
MOUNTING SURFACE TO TERMINAL END DISTANCE |
2.609 INCHES NOMINAL |
| CRTK |
SWITCH TERMINAL TYPE |
PIN |
| CPRJ |
TRIP RELEASE METHOD |
MAGNETIC ALL LOCATIONS |
| AEBQ |
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH |
1.032 INCHES NOMINAL |
| AAQL |
BODY STYLE |
MULTIPOLE-MULTIPLE ACTUATOR TYPE |
| AEBY |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH |
2.750 INCHES NOMINAL |
| AEGJ |
SWITCH CONTACT ARRANGEMENT |
SINGLE POLE, DOUBLE THROW |
| ADAT |
BODY WIDTH |
3.096 INCHES NOMINAL |
| TTQY |
TERMINAL TYPE AND QUANTITY |
10 THREADED STUD |
| CPRF |
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS |
125.0 DC FIRST LOCATION 125.0 DC SECOND LOCATION 125.0 DC THIRD LOCATION 30.0 DC FOURTH LOCATION |
| APNQ |
III ARC QUENCHING METHOD |
MAGNETIC BLOWOUT |
| CPRW |
ACTUATOR FUNCTION |
TRIP-RESET |
| CPRH |
CIRCUIT PROTECTION TYPE |
OVERCURRENT FIRST LOCATION OVERCURRENT SECOND LOCATION OVERCURRENT THIRD LOCATION OVERVOLTAGE FOURTH LOCATION |
| AJEC |
BOSS HEIGHT |
0.218 INCHES NOMINAL |
| CPRQ |
RESET METHOD |
MANUAL |
| CPRY |
EXTERNAL ACTUATOR LINKAGE ARRANGEMENT |
ONE, TWO, THREE, AND FOUR LINKED |
| CQXF |
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED |
FUNGUS RESISTANT AND MOISTURE RESISTANT |
| ABTD |
MOUNTING SLOT WIDTH |
0.164 INCHES NOMINAL |
| BBRJ |
III SPECIAL HANDLING FEATURE |
MAGNETIC |
| AFJN |
III FRAGILITY FACTOR |
MODERATELY RUGGED |
| AXHR |
MOUNTING FACILITY TYPE AND QUANTITY |
8 THREADED HOLE AND 8 SLOT |
| CPRG |
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS |
5000.0 DC ALL LOCATIONS |
| CPRZ |
AUXILIARY SWITCH FUNCTION AND QUANTITY |
1 ALARM |
| CPSM |
INTERNAL TRIP RELEASE CONFIGURATION |
SERIES TRIP FIRST LOCATION SERIES TRIP SECOND LOCATION SERIES TRIP THIRD LOCATION RELAY TRIP FOURTH LOCATION |
| THSD |
THREAD SERIES DESIGNATOR |
UNC |
| CPLM |
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE |
60.0 AMPERES DC FIRST LOCATION 60.0 AMPERES DC SECOND LOCATION 50.0 AMPERES DC THIRD LOCATION |
| ADTV |
CASE MATERIAL |
PLASTIC |
| CPRR |
MAIN CONTACT TRIPPING MECHANISM TYPE |
TRIP FREE |
| CSSX |
SWITCH CURRENT RATING AND TYPE IN AMPS |
5.0 AC |
| CPRT |
MANUAL ACTUATOR TYPE AND QUANTITY |
4 TOGGLE |
| CMLP |
THREAD QUANTITY PER INCH |
32 |
| BBRG |
III STORAGE TYPE |
GENERAL PURPOSE WAREHOUSE |
| CQJX |
NOMINAL THREAD SIZE |
0.138 INCHES |
| AEBP |
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH |
3.546 INCHES NOMINAL |
| CQWN |
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT |
45.000 MINIMUM AT 200 PCT AND 100.000 MAXIMUM AT 200 PCT FIRST LOCATION 45.000 MINIMUM AT 200 PCT AND 100.000 MAXIMUM AT 200 PCT SECOND LOCATION 45.000 MINIMUM AT 200 PCT AND 100.000 MAXIMUM AT 200 PCT THIRD LOCATION |
| CPRL |
TRIP RELEASE CHARACTERISTIC |
TIME DELAY FIRST LOCATION TIME DELAY SECOND LOCATION TIME DELAY THIRD LOCATION INSTANTANEOUS FOURTH LOCATION |
| CQSM |
SWITCH LOCATION AND POSITION DESIGNATION |
INTERNAL AT POLE FOUR |
| CPRN |
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT |
125.0 FIRST LOCATION 125.0 SECOND LOCATION 125.0 THIRD LOCATION |
| CSWP |
SWITCH VOLTAGE RATING AND TYPE IN VOLTS |
125.0 AC |
| AKPX |
POLE QUANTITY |
4 |
| CPRX |
ACTUATOR POSITION DESIGNATION |
AT EACH POLE |
| AEHA |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH |
1.032 INCHES NOMINAL |
| ADAQ |
BODY LENGTH |
5.844 INCHES NOMINAL |