| MRC |
Requirement Statement |
Characteristics |
| CXQR |
CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE |
5.000 AMPERES RESISTIVE DC AND 20.000 AMPERES RESISTIVE AC |
| ABMK |
OVERALL WIDTH |
3.251 INCHES NOMINAL |
| ABKW |
OVERALL HEIGHT |
2.813 INCHES NOMINAL |
| AFWD |
HOUSING LENGTH |
4.500 INCHES NOMINAL |
| CXQQ |
ACTUATOR MOVEMENT |
8.2 PRETRAVEL DEGREES NOMINAL AND 11.5 OVERTRAVEL DEGREES NOMINAL AND 2.8 DIFFERENTIAL DEGREES NOMINAL |
| AFUQ |
ACTUATOR STYLE |
ROUND |
| CRRM |
SWITCH RELEASE FORCE |
80.0 INCH-OUNCES NOMINAL |
| CRLD |
NONPILE-UP CONTACT ARRANGEMENT |
1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY SINGLE SWITCH UNIT |
| AKNA |
INCLOSURE TYPE |
FULLY INCLOSED |
| AAQL |
BODY STYLE |
HOLE MOUNTED |
| CSJN |
SWITCH ACTUATING FORCE |
176.0 INCH-OUNCES NOMINAL |
| AXGY |
MOUNTING METHOD |
BRACKET AND UNTHREADED HOLE |
| AFWH |
CENTER TO CENTER DISTANCE BETWEEN HOUSING MOUNTING FACILITIES PARALLEL TO LENGTH |
2.438 INCHES NOMINAL |
| ABFE |
HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION |
EXPLOSION PROOF |
| AFUU |
ACTUATOR FREE POSITION HEIGHT |
0.656 INCHES NOMINAL |
| AFWJ |
CENTER TO CENTER DISTANCE BETWEEN HOUSING MOUNTING FACILITIES PARALLEL TO WIDTH |
2.813 INCHES NOMINAL |
| AFWE |
HOUSING WIDTH |
3.251 INCHES NOMINAL |
| AFXE |
MAXIMUM VOLTAGE RATING IN VOLTS |
115.0 AC AND 125.0 DC |
| AFWC |
HOUSING HEIGHT |
2.406 INCHES NOMINAL |
| TTQY |
TERMINAL TYPE AND QUANTITY |
3 SCREW |
| ABHP |
OVERALL LENGTH |
4.500 INCHES NOMINAL |