| MRC |
Requirement Statement |
Characteristics |
| SR-1 |
SPEC/STD CONTROLLING DATA |
|
| AEBT |
TERMINAL DIAMETER |
0.024 INCHES MINIMUM AND 0.026 INCHES MAXIMUM |
| SR-1 |
NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE |
MIL-PRF-23419/2 |
| ZZZK |
SPECIFICATION/STANDARD DATA |
81349-MIL-F-23419/2 GOVERNMENT SPECIFICATION |
| CBBL |
FEATURES PROVIDED |
NONRENEWABLE FUSIBLE ELEMENT |
| AFXE |
MAXIMUM VOLTAGE RATING IN VOLTS |
125.0 AC AND 125.0 DC |
| ADAQ |
BODY LENGTH |
0.333 INCHES MINIMUM AND 0.363 INCHES MAXIMUM |
| ADAV |
OVERALL DIAMETER |
0.250 INCHES NOMINAL |
| CSQN |
SHORT-CIRCUIT/INTERRUPT CURRENT RATING IN AMPS |
10000.0 |
| SR-1 |
MANUFACTURERS CODE |
81349 |
| AFXH |
INTERRUPTION INDICATOR METHOD |
VISIBLE ELEMENT |
| AEBJ |
CONTINUOUS CURRENT RATING IN AMPS |
0.010 |
| ABHP |
OVERALL LENGTH |
0.503 INCHES MINIMUM AND 0.533 INCHES MAXIMUM |
| AAQL |
BODY STYLE |
PLUG-IN TYPE |
| AFXF |
CIRCUIT OVER-CURRENT INTERRUPTION TYPE |
NORMAL INSTANTANEOUS |
| AEBX |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO DIAMETER |
0.100 INCHES MINIMUM AND 0.108 INCHES MAXIMUM |
| ABJT |
TERMINAL LENGTH |
0.170 INCHES NOMINAL |
| ABDN |
TERMINAL SURFACE TREATMENT |
NICKEL OR TIN PLATE |
| SR-1 |
DEFINITIVE GOVERNMENT SPEC/STD REFERENCE |
FM02A125V1/100A |
| ABDM |
III TERMINAL MATERIAL |
COPPER |