| MRC |
Requirement Statement |
Characteristics |
| AXGY |
MOUNTING METHOD |
BRACKET |
| AFDS |
LONGEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS |
5.375 INCHES NOMINAL |
| CTYC |
CONTACT ADJUSTABILITY |
ACTUATION POINT ADJUSTABLE |
| AJZC |
PRESSURE SWITCH TYPE |
GAGE |
| CTYM |
CONTACT ADJUSTMENT RANGE |
15.00 TO 400.00 ACTUATION POINT POUNDS PER SQUARE INCH |
| CQJX |
NOMINAL THREAD SIZE |
0.250 INCHES SINGLE PRESSURE CONNECTION |
| THSD |
THREAD SERIES DESIGNATOR |
NPT SINGLE PRESSURE CONNECTION |
| CMLP |
THREAD QUANTITY PER INCH |
18 SINGLE PRESSURE CONNECTION |
| ABMK |
OVERALL WIDTH |
6.375 INCHES NOMINAL |
| CTZB |
CONTACT VOLTAGE RATING IN VOLTS |
460.0 AC AT SEA LEVEL SINGLE VOLTAGE |
| ABHP |
OVERALL LENGTH |
7.375 INCHES NOMINAL |
| FEAT |
SPECIAL FEATURES |
SPLASH-PROOF HOUSING 1/2-14 NPT CONDUIT CONNECTION |
| AFDV |
LONGEST VERTICAL DISTANCE BETWEEN MOUNTING CENTERS |
3.500 INCHES NOMINAL |
| CTHF |
CONTACT LOAD CURRENT RATING |
3.0 AMPERES RESISTIVE LOAD SINGLE VOLTAGE |
| CSCF |
TERMINAL TYPE |
SCREW |
| CRLD |
NONPILE-UP CONTACT ARRANGEMENT |
1 POLE, DOUBLE THROW, BOTH POSITIONS MAINTAINED |
| ABKW |
OVERALL HEIGHT |
2.500 INCHES NOMINAL |
| CQYJ |
MOUNTING FACILITY PATTERN |
FOUR POSITION RECTANGULAR |