| MRC |
Requirement Statement |
Characteristics |
| CQYJ |
MOUNTING FACILITY PATTERN |
TWO POSITION IN-LINE |
| AEJN |
DISTANCE BETWEEN MOUNTING FACILITY CENTERS |
0.937 INCHES NOMINAL |
| ABPM |
BODY DIAMETER |
0.540 INCHES MINIMUM AND 0.640 INCHES MAXIMUM |
| CTHF |
CONTACT LOAD CURRENT RATING |
2.0 AMPERES RESISTIVE LOAD AND 1.0 AMPERES INDUCTIVE LOAD AND 500.0 MILLIAMPERES LAMP LOAD FIRST VOLTAGE 5.0 AMPERES RESISTIVE LOAD AND 2.5 AMPERES INDUCTIVE LOAD AND 1.0 AMPERES LAMP LOAD SECOND VOLTAGE 5.0 AMPERES RESISTIVE LOAD AND 2.5 AMPERES INDUCTIVE LOAD AND 1.0 AMPERES LAMP LOAD THIRD VOLTAGE |
| SR-1 |
SPEC/STD CONTROLLING DATA |
|
| SR-1 |
DEFINITIVE GOVERNMENT SPEC/STD REFERENCE |
M24236/1-0485 |
| AWTN |
OPERATING TEMP RATING |
-65.0 DEG FAHRENHEIT MINIMUM AND 500.0 DEG FAHRENHEIT MAXIMUM |
| MEDA |
MEDIA FOR WHICH DESIGNED |
GAS OR LIQUID |
| ADAU |
BODY HEIGHT |
0.280 INCHES MINIMUM AND 0.395 INCHES MAXIMUM |
| AEBV |
UNTHREADED MOUNTING HOLE DIAMETER |
0.140 INCHES NOMINAL |
| ABKW |
OVERALL HEIGHT |
0.659 INCHES NOMINAL |
| CRTL |
CRITICALITY CODE JUSTIFICATION |
FEAT |
| STYL |
STYLE DESIGNATOR |
DISC W/FLANGE |
| FEAT |
SPECIAL FEATURES |
ITEM MUST COMPLY WITH REQUIREMENTS OF DESC PRODUCTION STANDARD NO. L01720,FOR NAVY NUCLEAR PROPULSION PLANT PRODUCTS ONLY |
| SR-1 |
MANUFACTURERS CODE |
81349 |
| CTZB |
CONTACT VOLTAGE RATING IN VOLTS |
115.0 AC AT SEA LEVEL FIRST VOLTAGE 28.0 DC AT SEA LEVEL SECOND VOLTAGE 28.0 DC AT ALTITUDE THIRD VOLTAGE |
| ABHP |
OVERALL LENGTH |
1.160 INCHES MINIMUM AND 1.260 INCHES MAXIMUM |
| FREQ |
FREQUENCY IN HERTZ |
60.0 FIRST VOLTAGE |
| CBBL |
FEATURES PROVIDED |
HERMETICALLY SEALED CASE |
| CSCF |
TERMINAL TYPE |
TAB, SOLDER LUG |
| CTYX |
CONTACT STIMULUS RATING |
125.00 ACTUATION POINT NOMINAL DEGREES FAHRENHEIT AND 150.00 DEACTUATION POINT NOMINAL DEGREES FAHRENHEIT |
| AKBY |
TEMP SENSING ELEMENT TYPE |
INTERNAL SENSOR |
| CTYC |
CONTACT ADJUSTABILITY |
DEACTUATION POINT NOT ADJUSTABLE AND ACTUATION POINT NOT ADJUSTABLE |
| ABTD |
MOUNTING SLOT WIDTH |
0.140 INCHES NOMINAL |
| AXGY |
MOUNTING METHOD |
BRACKET AND SLOT AND UNTHREADED HOLE |
| SR-1 |
NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE |
MIL-PRF-24236/1 |
| CRLD |
NONPILE-UP CONTACT ARRANGEMENT |
1 POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION |
| CQGB |
CONTACT ACTION STIMULUS |
DECREASE |