MRC |
Requirement Statement |
Characteristics |
AHNC |
CONNECTION STYLE |
INVERTED FLARE 1ST END |
CRWL |
INSIDE SURFACE CONDITION |
SMOOTH |
CQBD |
BURST TEST PRESSURE |
28000.0 POUNDS PER SQUARE INCH |
THSD |
THREAD SERIES DESIGNATOR |
NPT 1ST END |
CRXX |
MEASURING METHOD AND LENGTH |
120.000 INCHES NOMINAL OVERALL |
CQJX |
NOMINAL THREAD SIZE |
0.250 INCHES 1ST END |
ACKH |
MINIMUM INSIDE BENDING RADIUS |
5.000 INCHES |
CRDW |
HYDROSTATIC TEST PRESSURE |
15000.0 POUNDS PER SQUARE INCH |
CQGM |
MAXIMUM OPERATING PRESSURE |
7000.0 POUNDS PER SQUARE INCH |
AKUU |
END CONNECTION DESIGN |
STRAIGHT 1ST END |
CQCS |
LAYER COMPOSITION AND LOCATION |
1ST LAYER SPIRALLY LAID STEEL WIRE 2ND LAYER SPIRALLY LAID STEEL WIRE 3RD LAYER BRAIDED STEEL WIRE OUTER LAYER MOLDED RUBBER |
ADJM |
(NON-CORE DATA) INNER CONVEYING TUBE MATERIAL |
RUBBER, SYNTHETIC |
CQRB |
SEAT ANGLE |
30.0 DEGREES 1ST END |
AARX |
INSIDE DIAMETER |
0.250 INCHES NOMINAL |
AAGR |
CROSS-SECTIONAL SHAPE STYLE |
ROUND |
CQHW |
(NON-CORE DATA) FIRST END FITTING/COMPONENT AND SURFACE TREATMENT |
COMPLETE FITTING CADMIUM, DICHROMATE TREATED |
AAJF |
THREAD DIRECTION |
RIGHT-HAND 1ST END |
MEDA |
MEDIA FOR WHICH DESIGNED |
HYDRAULIC FLUID, WATER BASE SINGLE RESPONSE |
AWLS |
CONNECTION TYPE |
THREADED EXTERNAL PIPE 1ST END |
CQBB |
(NON-CORE DATA) SECOND END RELATIONSHIP WITH FIRST END |
IDENTICAL |
CQBG |
(NON-CORE DATA) FIRST END SWIVEL ACTION CAPABILITY |
NOT INCLUDED |
ABKV |
OUTSIDE DIAMETER |
0.734 INCHES NOMINAL |
CRJM |
OUTER COVERING ENVIRONMENTAL PROTECTION |
HYDRAULIC SOLUTION RESISTANT |
ADJS |
EXTERIOR COLOR |
BLACK |
ABJH |
TEMP RATING |
-40.0 DEG FAHRENHEIT AND 200.0 DEG FAHRENHEIT SINGLE RESPONSE |
CQGH |
(NON-CORE DATA) FIRST END FITTING/COMPONENT AND MATERIAL |
COMPLETE FITTING STEEL |