MRC |
Requirement Statement |
Characteristics |
AEBV |
UNTHREADED MOUNTING HOLE DIAMETER |
0.688 INCHES NOMINAL |
AXHR |
MOUNTING FACILITY TYPE AND QUANTITY |
4 UNTHREADED HOLE |
FEAT |
SPECIAL FEATURES |
THREE FILTERED FUNCTIONS |
ADAQ |
BODY LENGTH |
37.000 INCHES NOMINAL |
ABHP |
OVERALL LENGTH |
39.000 INCHES NOMINAL |
CRDC |
III MAXIMUM DIELECTRIC WITHSTANDING DC VOLTAGE |
1.2 KILOVOLTS AT SEA LEVEL |
AEBY |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH |
25.000 INCHES NOMINAL |
CQRG |
III BODY MATERIAL |
METAL |
AHAS |
LOAD IMPEDANCE PER FUNCTION |
50.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION 50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION 50.0 OHMS 3RD RADIO INTERFERENCE 3RD FUNCTION |
AHAQ |
SOURCE IMPEDANCE RATING PER FUNCTION |
50.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION 50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION 50.0 OHMS 3RD RADIO INTERFERENCE 3RD FUNCTION |
STYL |
STYLE DESIGNATOR |
RECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES |
AHBC |
OPERATING CURRENT RATING PER FUNCTION IN AMPS |
50.0 1ST RADIO INTERFERENCE 1ST FUNCTION 50.0 2ND RADIO INTERFERENCE 2ND FUNCTION 50.0 3RD RADIO INTERFERENCE 3RD FUNCTION |
PKWT |
III UNPACKAGED UNIT WEIGHT |
145.000 POUNDS |
ADAT |
BODY WIDTH |
20.000 INCHES NOMINAL |
AHBE |
MAXIMUM VOLTAGE DROP PER FUNCTION |
2.77 VOLTS AC 1ST RADIO INTERFERENCE AND 6.0 VOLTS DC 1ST RADIO INTERFERENCE 1ST FUNCTION 2.77 VOLTS AC 2ND RADIO INTERFERENCE AND 6.0 VOLTS DC 2ND RADIO INTERFERENCE 2ND FUNCTION 2.77 VOLTS AC 3RD RADIO INTERFERENCE AND 6.0 VOLTS DC 3RD RADIO INTERFERENCE 3RD FUNCTION |
CQDW |
FUNCTIONAL TERMINAL TYPE AND QUANTITY |
3 TAB, SOLDER LUG INPUT 1ST FUNCTION 3 TAB, SOLDER LUG OUTPUT 2ND FUNCTION |
AHBL |
III PRINCIPAL CIRCUITRY TYPE PER FUNCTION |
INDUCTANCE-CAPACITANCE 1ST RADIO INTERFERENCE 1ST FUNCTION INDUCTANCE-CAPACITANCE 2ND RADIO INTERFERENCE 2ND FUNCTION INDUCTANCE-CAPACITANCE 3RD RADIO INTERFERENCE 3RD FUNCTION |
AKNA |
INCLOSURE TYPE |
HERMETICALLY SEALED |
AEHA |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH |
22.000 INCHES NOMINAL |
CQGC |
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION |
277.0 VOLTS AC 1ST RADIO INTERFERENCE AND 600.0 VOLTS DC 1ST RADIO INTERFERENCE 1ST FUNCTION 277.0 VOLTS AC 2ND RADIO INTERFERENCE AND 600.0 VOLTS DC 2ND RADIO INTERFERENCE 2ND FUNCTION 277.0 VOLTS AC 3RD RADIO INTERFERENCE AND 600.0 VOLTS DC 3RD RADIO INTERFERENCE 3RD FUNCTION |
CBBL |
FEATURES PROVIDED |
CORROSION RESISTANT |
AHCG |
III MAXIMUM TEMP RISE |
25.0 DEG CELSIUS |
AHBB |
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ |
60.0 1ST RADIO INTERFERENCE 1ST FUNCTION 60.0 2ND RADIO INTERFERENCE 2ND FUNCTION 60.0 3RD RADIO INTERFERENCE 3RD FUNCTION |
ADAU |
BODY HEIGHT |
5.000 INCHES NOMINAL |
AFGA |
III OPERATING TEMP RANGE |
-55.0 TO 85.0 DEG CELSIUS |