Home > Resistor > FSC 5905 > 5905-00-162-3461

5905-00-162-3461, 5905001623461 NSN Information

Request for Quote

Manufacturer Part Number(s):40509-10K, 56PR10K, 70P103, MIL-R-22097/2, RJ12FP103, RJ12FP103FM, RJ12P103K

FSC NIIN ITEM NAME
5905 001623461 RESISTOR,VARIABLE,NONWIRE WOUND,
INC ESDC HMIC
3740 B N

5905-00-162-3461 MCRD (Master Cross Reference Data)

Mfg. Part # Mfg. Name CAGE RNCC RNVC ISC MSDS SADC DAC HCC
40509-10K L-3 SERVICES INC. 82152 E 8 1
56PR10K BI TECHNOLOGIES CORPORATION 73138 E 8 1
70P103 IV-ELECTRONIC KLAUS VESPERMANN KG C7407 5 2 1
70P103 VISHAY THIN FILM LLC 02111 5 1 1
MIL-R-22097/2 MILITARY SPECIFICATIONS 81349 4 1 1
RJ12FP103 MILITARY SPECIFICATIONS 81349 2 2 1
RJ12FP103FM MILITARY SPECIFICATIONS 81349 C 1 1 N
RJ12P103K MILITARY SPECIFICATIONS 81349 C 1 1 N

5905-00-162-3461 Characteristics

MRC Requirement Statement Characteristics
CQCK ROTARY ACTUATOR TRAVEL IN ANGULAR DEG 6120.0 MINIMUM AND 9720.0 MAXIMUM
TTQY TERMINAL TYPE AND QUANTITY 3 PIN
CSDH AMBIENT TEMP IN DEG CELSIUS PER SECTION AT FULL RATED POWER 85.0 SINGLE SECTION
SR-1 DEFINITIVE GOVERNMENT SPEC/STD REFERENCE RJ12FP103
CRSX ACTUATOR TRAVEL CONTROL FEATURE CLUTCH
AKPV MOUNTING FACILITY QUANTITY 2
SR-1 SPEC/STD CONTROLLING DATA
ADAU BODY HEIGHT 0.315 INCHES NOMINAL
ADAT BODY WIDTH 0.190 INCHES NOMINAL
AGTP LATERAL DISTANCE BETWEEN MOUNTING HOLE CENTERS 1.000 INCHES NOMINAL
AEFD ACTUATOR TYPE SINGLE SHAFT
AXGY MOUNTING METHOD TERMINAL AND UNTHREADED HOLE
ABWV SHAFT DIAMETER 0.058 INCHES NOMINAL
SR-1 NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE MIL-R-22097/2
AARG RELIABILITY INDICATOR NOT ESTABLISHED
ABXF SHAFT LENGTH 0.070 INCHES NOMINAL
AEFH EFFECTIVE ELECTRICAL ROTATION IN DEG ANGULAR ROTATION 6120.0 MINIMUM AND 9720.0 MAXIMUM
CRFJ TEMP COEFFICIENT OF RESISTANCE PER SECTION IN PPM PER DEG CELSIUS -100.0 TO 100.0 SINGLE SECTION
AEHT CENTER TO CENTER DISTANCE BETWEEN TERMINALS 0.900 INCHES NOMINAL
CSDL STANDARD TAPER CURVE PER SECTION A SINGLE SECTION
ABTB MOUNTING HOLE DIAMETER 0.093 INCHES NOMINAL
SR-1 MANUFACTURERS CODE 81349
CQCC ELECTRICAL RESISTANCE PER SECTION 10.0 KILOHMS SINGLE SECTION
CRSS RESISTANCE TOLERANCE PER SECTION IN PERCENT -10.0 TO 10.0 SINGLE SECTION
APXH TERMINAL LOCATION LOWER ADJACENT SIDE SINGLE ROW
AEDX SHAFT STYLE ROUND, SLOTTED
CQGN AMBIENT TEMP IN DEG CELSIUS PER SECTION AT ZERO PERCENT RATED POWER 150.0 SINGLE SECTION
CRGD POWER DISSIPATION RATING PER SECTION IN WATTS 0.75 FREE AIR SINGLE SECTION
ABJT TERMINAL LENGTH 0.500 INCHES NOMINAL
ZZZK SPECIFICATION/STANDARD DATA 81349-MIL-R-22097/2 GOVERNMENT SPECIFICATION
ADAQ BODY LENGTH 1.250 INCHES NOMINAL
CQCM CENTER TO CENTER DISTANCE BETWEEN CENTER TERMINAL AND OUTSIDE TERMINAL 0.700 INCHES NOMINAL
AAQL BODY STYLE RECTANGULAR W/MOUNTING HOLES/SLOTS
AAPN SECTION QUANTITY 1