MRC |
Requirement Statement |
Characteristics |
SR-1 |
NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE |
MIL-R-55182/1 |
CBME |
(NON-CORE DATA) CUBIC MEASURE |
0.004 CUBIC INCHES |
AAQH |
TEMP RANGE OF TEMP COEFFICIENT IN DEG CELSIUS |
-55.0 TO 175.0 |
AAQG |
AMBIENT TEMP IN DEG CELSIUS AT ZERO PERCENT RATED POWER |
175.0 |
AARH |
RELIABILITY FAILURE RATE LEVEL IN PERCENT |
0.001 |
SR-1 |
SPEC/STD CONTROLLING DATA |
|
PKWT |
III UNPACKAGED UNIT WEIGHT |
0.35 GRAMS |
AARG |
RELIABILITY INDICATOR |
ESTABLISHED |
ABJT |
TERMINAL LENGTH |
1.000 INCHES MINIMUM AND 1.625 INCHES MAXIMUM |
ADAQ |
BODY LENGTH |
0.204 INCHES MINIMUM AND 0.281 INCHES MAXIMUM |
AAQZ |
INCLOSURE METHOD |
ENCAPSULATED |
ZZZK |
SPECIFICATION/STANDARD DATA |
81349-MIL-R-55182/1 GOVERNMENT SPECIFICATION |
AAQF |
AMBIENT TEMP IN DEG CELSIUS AT FULL RATED POWER |
125.0 |
AARB |
TERMINAL TYPE |
WIRE LEAD |
STYL |
STYLE DESIGNATOR |
AXIAL TERMINAL EACH END |
ABPM |
BODY DIAMETER |
0.078 INCHES MINIMUM AND 0.140 INCHES MAXIMUM |
SR-1 |
MANUFACTURERS CODE |
81349 |
AEFB |
POWER DISSIPATION RATING IN WATTS |
0.100 FREE AIR |
SR-1 |
DEFINITIVE GOVERNMENT SPEC/STD REFERENCE |
RNC55J2430FS |
AAPQ |
RESISTANCE TOLERANCE IN PERCENT |
-1.000 TO 1.000 |
AAPE |
TEMP COEFFICIENT OF RESISTANCE IN PPM PER DEG CELSIUS |
-25.0 TO 25.0 |
AARF |
MIL-STD-1276 WIRE LEAD TYPE DESIGNATOR |
C |
AAPP |
ELECTRICAL RESISTANCE |
243.000 OHMS |