| MRC |
Requirement Statement |
Characteristics |
| ADAU |
BODY HEIGHT |
0.367 INCHES MINIMUM AND 0.390 INCHES MAXIMUM |
| ABPM |
BODY DIAMETER |
0.610 INCHES MINIMUM AND 0.630 INCHES MAXIMUM |
| CQYJ |
MOUNTING FACILITY PATTERN |
TWO POSITION IN-LINE |
| MEDA |
MEDIA FOR WHICH DESIGNED |
GAS |
| AXGY |
MOUNTING METHOD |
BRACKET |
| ABMK |
OVERALL WIDTH |
0.680 INCHES NOMINAL |
| CQGB |
CONTACT ACTION STIMULUS |
INCREASE |
| CTHF |
CONTACT LOAD CURRENT RATING |
2.0 AMPERES RESISTIVE LOAD AND 1.0 AMPERES INDUCTIVE LOAD AND 500.0 MILLIAMPERES LAMP LOAD FIRST VOLTAGE 5.0 AMPERES RESISTIVE LOAD AND 2.5 AMPERES INDUCTIVE LOAD AND 1.0 AMPERES LAMP LOAD SECOND VOLTAGE 5.0 AMPERES RESISTIVE LOAD AND 2.5 AMPERES INDUCTIVE LOAD AND 1.0 AMPERES LAMP LOAD THIRD VOLTAGE |
| SR-1 |
SPEC/STD CONTROLLING DATA |
|
| AWTN |
OPERATING TEMP RATING |
-65.0 DEG FAHRENHEIT MINIMUM AND 500.0 DEG FAHRENHEIT MAXIMUM |
| AEJN |
DISTANCE BETWEEN MOUNTING FACILITY CENTERS |
0.928 INCHES MINIMUM |
| ABHP |
OVERALL LENGTH |
1.240 INCHES MINIMUM AND 1.260 INCHES MAXIMUM |
| CTYX |
CONTACT STIMULUS RATING |
180.00 ACTUATION POINT MINIMUM DEGREES FAHRENHEIT AND 190.00 ACTUATION POINT MAXIMUM DEGREES FAHRENHEIT AND 165.00 DEACTUATION POINT MINIMUM DEGREES FAHRENHEIT AND 175.00 DEACTUATION POINT MAXIMUM DEGREES FAHRENHEIT AND 15.00 DIFFERENTIAL POINT NOMINAL DEGREES FAHRENHEIT |
| STYL |
STYLE DESIGNATOR |
DISC W/FLANGE |
| SR-1 |
MANUFACTURERS CODE |
81349 |
| CTZB |
CONTACT VOLTAGE RATING IN VOLTS |
115.0 AC AT SEA LEVEL FIRST VOLTAGE 28.0 DC AT SEA LEVEL SECOND VOLTAGE 28.0 DC AT ALTITUDE THIRD VOLTAGE |
| FREQ |
FREQUENCY IN HERTZ |
60.0 FIRST VOLTAGE |
| CBBL |
FEATURES PROVIDED |
HERMETICALLY SEALED CASE |
| CSCF |
TERMINAL TYPE |
TAB, SOLDER LUG |
| SR-1 |
NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE |
MILS24236-1 |
| AKBY |
TEMP SENSING ELEMENT TYPE |
INTERNAL SENSOR |
| ABKW |
OVERALL HEIGHT |
0.627 INCHES MINIMUM AND 0.650 INCHES MAXIMUM |
| CRLD |
NONPILE-UP CONTACT ARRANGEMENT |
1 POLE, SINGLE THROW, NORMALLY CLOSED, MOMENTARY ACTION |
| CTYC |
CONTACT ADJUSTABILITY |
DEACTUATION POINT NOT ADJUSTABLE AND ACTUATION POINT NOT ADJUSTABLE |
| SR-1 |
DEFINITIVE GOVERNMENT SPEC/STD REFERENCE |
M24236/1-007 |