| MRC |
Requirement Statement |
Characteristics |
| MEDA |
MEDIA FOR WHICH DESIGNED |
GAS OR LIQUID |
| AXGY |
MOUNTING METHOD |
UNTHREADED HOLE |
| CTHF |
CONTACT LOAD CURRENT RATING |
1.0 AMPERES RESISTIVE LOAD FIRST VOLTAGE 2.0 AMPERES RESISTIVE LOAD SECOND VOLTAGE 1.0 AMPERES RESISTIVE LOAD THIRD VOLTAGE 2.0 AMPERES RESISTIVE LOAD FOURTH VOLTAGE |
| CTZB |
CONTACT VOLTAGE RATING IN VOLTS |
240.0 AC AT SEA LEVEL FIRST VOLTAGE 120.0 AC AT SEA LEVEL SECOND VOLTAGE 240.0 DC AT SEA LEVEL THIRD VOLTAGE 120.0 DC AT SEA LEVEL FOURTH VOLTAGE |
| CTYM |
CONTACT ADJUSTMENT RANGE |
40.00 TO 80.00 ACTUATION POINT DEGREES FAHRENHEIT AND 37.50 TO 77.50 DEACTUATION POINT DEGREES FAHRENHEIT |
| CBBL |
FEATURES PROVIDED |
ELECTRICAL ACCESS PORT |
| CTYS |
CONTACT ADJUSTMENT TYPE |
EXTERNAL DEACTUATION POINT KNOB WITH SCALE AND EXTERNAL ACTUATION POINT KNOB WITH SCALE |
| STYL |
STYLE DESIGNATOR |
RECTANGULAR |
| CSCF |
TERMINAL TYPE |
SCREW |
| AKBY |
TEMP SENSING ELEMENT TYPE |
BELLOWS |
| CTYC |
CONTACT ADJUSTABILITY |
DEACTUATION POINT ADJUSTABLE AND ACTUATION POINT ADJUSTABLE |
| CRLD |
NONPILE-UP CONTACT ARRANGEMENT |
1 POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION |
| CQGB |
CONTACT ACTION STIMULUS |
DECREASE |